Overview
Dimensions: 324.8 × 113.7 × 28.3 mm (12.8 × 4.5 × 1.1")
Integrated Camera: ✔
NFC Card & Keyfob Access: ✔
PIN Access: ✔
QR Code Unlock: ✔
Apple/Google Wallet: ✔
Mobile Unlock: ✔
Face Unlock: ✔
UniFi Application Suite: Access
Two-Way Intercom & Doorbell Access: ✔
NDAA Compliant: ✔
UL 294 Level: Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Weatherproofing: IP65
Mechanical
Weight: Device: 965 g (2.1 lb) Bracket: 445 g (1 lb)
Enclosure Material: Aluminum alloy, UV-stabilized polycarbonate, glass
Mount Material: Powder-coated stainless steel
Mounting: Wall mount, adapter to the gooseneck pedestal (Included) Surface angle, flush mount, sunshield kit (Optional)
Hardware
Indoor and Outdoor Use: Yes Networking Interface: (1) GbE RJ45 port Connectivity: BLE 4.2, NFC
Power Method: PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Max. Power Consumption: 13W Supported Voltage Range: 48V DC
Video Max. Frame Rate: 30 FPS Resolution: 2MP 1200 × 1600 (3:4)
Optics Resolution: 8 MP (2448 × 3264) Field of View: H: 79.4°, V: 97.5°, D: 118.2° Sensors: Proximity sensor, ALS sensor
Display
Size: 177 mm (7") diagonal Screen Technology: Capacitive multi-touch Luminance: Max. 1000 nits (Typical)
Screen Orientation: Portrait Resolution: 1024 × 600 px Microphone: ✔ Speaker: ✔
NFC Frequency: 13.56 MHz NFC Read Range: < 30 mm (1.18'')
NFC Technology: ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) MIFARE Classic / MIFARE DESFIRE Sony FeliCa™ (ID only) NFC Forum tags T1T, T2T, T3T, T4T and T5T ECP 2.0
LEDs: Amber Buttons: (1) Factory reset
PoE Cabling Requirements: Cat 5e minimum. Minimum conductor gauge: 26 AWG (0.13 mm²) patch cords; 24 AWG (0.21 mm²) horizontal/riser cable.
UL 294 Statement: Compliance with IEEE 802.3 specifications was not verified as part of UL 294. Equipment intended to comply with ANSI/NFPA 70 Article 725.121.
CAN/ULC-60839-11-1 Grade: Grade assignment: I
Certifications: CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document: UA-G3-Intercom, V01
Ambient Operating Temperature: Device: -30 to 60° C (-22 to 140° F) Display: -25 to 60° C (-13 to 140° F)
Ambient Operating Humidity: 5 to 90% noncondensing